RightestGS300 BLOOD GLUCOSE TEST STRIP INSERT
Intended Use
The Blood Glucose Monitoring System is used by individuals with diabetes.
It is for the checking on glucose levels in capillary whole blood (CB) from the finger, as an aid in
management of diabetes at home and clinical sites.
Rightest™ test Strips are intended for testing outside the body ( diagnostic use ) ( For self-
testing ) only.
The Rightest™ System tests the CB and provides results equivalent to a laboratory instrument.
- The Rightest™ Blood Glucose Test Strip is designed for use with the Rightest™ Blood Glucose
GM300/GM110 Meter.
- The Rightest™ Blood Glucose Monitoring System includes meter, Test Strips, Smart Code Key,
Check Key, control solutions, lancing device and lancets.
Rightest™
in vitro
Smart Code Key Installation (only for GM300 Meter)
1) With the Meter off, follow and direction to put the new
Smart Code Key into the track on code key base.
2) Push down the Smart Code Key until it snaps into the Smart
Code Key base.
Preparing the Lancing Device
(Please see detailed information in User Manual)
1) Unscrew the head of lancing device.
2) Load a lancet into the lancing device.
3) Twist off the protective cover of lancet and keep it
( You will need it after testing ).
4) Screw back the head of lancing device.
5) Twist the comfort dial of lancing device to select
the lancet depth. Start at 2 or 3.
For tougher skin, dial to a higher number.
6) Pull the plunger of lancing device until the end
and release your hand. Your lancing device is
ready. Then set it aside; you will need it in the
next step.
1) Wash and dry your hands. Take one strip from the vial. Close the vial cap immediately.
2) Insert the strip into the strip port on meter with the indication symbol facing up. Push the strip in
until it snaps and stops. The meter will turn on automatically.
3) Make sure the code number on the meter screen matches the code number on the test strip vial.
4) When you see the flashing blood drop, hold the
lancet device to side of your fingertip and press
the release button.
5) Gently squeeze your fingertip to get a drop of
blood. Our meter only needs a tiny blood sample.
Performing a Test
6) Touch and hold the drop to the edge of sample entry until you hear a " beep " and the view window
is totally filled with blood. If the view window is not totally filled with blood or the test does not start.
Then discard the test strip and repeat the test with a new test strip.
7) You will see the countdown mode on the screen. After 8 seconds, the test result appears. For more
information about your test results, please see your User Manual.
8) To remove the lancet, unscrew the head of lancing device and put the protective cover of lancet on
the table. Stick the lancet into the Protective cover by holding the lancing device it into a puncture-
proof container.
For more information on how to use your meter and understand your test results, see the User
Manual.
Test Result
- Blood glucose test results are shown on the meter as mg/dL or mmol/L, depending on which unit of
measurement you have chosen. Consult your doctor before making any changes to your diabetes
medication program.
- If your blood glucose result is unusually high or low, or if you question your results, repeat the test
with a new test strip. You can also run a quality control test with your Rightest™ Check Key and
Rightest™ Control Solutions to check your meter and strip. If the test result still remains unusually
high or low, contact your doctor immediately.
- If you are experiencing symptoms that are not consistent with your blood glucose test results and
you have followed all the instructions in this manual, contact your doctor immediately.
- The Rightest™ Meter displays results between 10 and 600 mg/dL or 0.6 and 33.3 mmol/L. If your
test result is below 10 mg/dL ( 0.6 mmol/L ), " Lo " will appear on the screen. Please repeat your test
again with another strip. If you still get a " Lo " result, you should immediately contact your doctor.
- If your test result is above 600 mg/dL ( 33.3 mmol/L ), " Hi " will appear on the screen. Please repeat
your test again with another strip. If you still get a " Hi " result, you should immediately contact your
doctor.
Expected values
Time
Fast for 8 hours:
Pre-diabetes
Diabetes
After eating or oral glucose tolerance test (in the 2 hours):
Pre-diabetes
Diabetes
Range (mg/dL)
100 – 125
>126
140 – 199
>200
Limitations
- Grossly lipemic ( fatty ) samples may interfere with some methodologies. To be aware of such
interferences, patients under the supervision of their physician should have baseline glucose values
established by a clinical laboratory method prior to starting home glucose monitoring. These
baseline values should be checked periodically thereafter.
- Meter read capillary blood glucose values may be significantly lower than " true glucose levels " in
the hyperglycemic-hyperosmolar state, with or without ketosis. Critically ill patients should not be
tested by the Rightest™ System, or tested with extreme caution.
- Caution is advised in the interpretation of glucose values below 50 mg/dL or above 250 mg/dL.
Consult a physician as soon as possible if values in this range are obtained.
Range (mmol/L)
5.6 – 6.9
>7.0
7.8 – 11.1
>11.1
1.0 1.4 2.0 3.0 .0µl µl µl µl 4 µl
We suggest you to take 1.4~2.5µl to do the test on
glucose monitoring system. Blood sample size
above 4.0µl is too much which might contaminate
the Smart Code Key.
1 2
1 2 3
4 5 6
1 2 3
5
7
NOTE
Different meter kit might be with different lancing device, please follow the instructions in
respective User Manual to make sure you perform the test correctly.
Sample Size Example
Precautions
- Check the expiration date printed on the package every time you use the strip. Do not use expired
test strips.
- Close the vial cap immediately after taking test strip out from the vial.
- Do not perform quality control test with expired control solution.
- Do not bend or twist the test strip. Damage of test strip may cause wrong result.
- Do not reuse test strips.
- Do not reuse lancets. Discard used lancets properly.
- Wait at least 30 minutes to perform a test if you have moved the meter to an area of different
temperature.
- If you want to purchase a new control solution, please contact your authorized Bionime
representative.
Warning
- Keep the test strips or vial cap away from children. They may cause a choking hazard. If a test strip
or vial cap is swallowed, contact your physician immediately.
4
6 8
GM300 Meter GM110 Meter
Test Procedure
REFER TO THE Rightest™ USER’S MANUAL FOR MORE DETAILED INFORMATION.
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1 - Sample Size Example

Rightest™ GS300 BLOOD GLUCOSE TEST STRIP INSERT Intended UseThe Blood Glucose Monitoring System is used by individuals wit

Seite 2 - Fingerstick (mg/dL)

- Healthcare professionals should evaluate their technique and their patients' technique at periodic intervals. To accomplish this, i

Kommentare zu diesen Handbüchern

ChrisTom 17 Apr 2024 | 22:41:43

Hello, im noob :)